CONVENTIONAL UT & PHASED ARRAY PROBESLatin America & Florida, USA

UT · 08

Ultrasonic calibration blocks: step blocks, V1/V2 and Phased Array

How to prepare a UT or PAUT calibration block inquiry: application, material, thicknesses, reflectors, drawing and documentation.

1. Define what the block must do

A request for an “ultrasonic block” leaves several decisions open. Will it support thickness measurement, adjustment of a probe and wedge assembly, or an amplitude reference? Before choosing a shape, state the operation you need to perform and the procedure that requires it.

You may also encounter the terms test block, reference block or calibration standard. In a quotation request, add a part number or drawing: the name alone does not identify every supply requirement.

2. Distinguish the block families

FamilyTypical purposeWhat to specify
Step blockKnown thickness references [1]Thicknesses, material and units
V1/V2 and variantsUT reference configurations [2]Model, drawing and revision
Reflector block for PAUTProcedure-defined adjustments, such as TCG [3]Reflector type, size and location

Do not treat these families as automatic substitutes. If the request names V1, V2, IIW or a commercial reference, obtain the drawing defining the variant and compare it with the requirement. Selection depends on application, material and procedure. [2]

3. For thickness gauging: describe each step

Step blocks provide several known thicknesses; flat, curved and thin-material versions exist. [1] For a quotation, list the thicknesses instead of simply requesting “five steps.” Confirm whether dimensions must be in millimetres or inches.

An example inquiry is: “I need a step block for my thickness gauge; attached are the working range, material and probe model.” Include the required contact area and a drawing if one is available. Do not turn a catalogue example into a specification without checking your application.

4. For Phased Array: specify the reflectors

In Eddyfi’s technical example for Capture, TCG adjustment uses identical reflectors, such as side-drilled holes or notches, at different depths. [3] This illustrates why “PAUT block” is not enough to identify a part.

Include instrument, probe and wedge references together with the block drawing. State the adjustment or verification you need to perform. If probes, wedges or cables are also required, list them as separate items so each component can be reviewed.

5. Specify the documentation precisely

Before comparing prices, confirm what must accompany the block: individual identification, a drawing, a dimensional record, a material certificate or a certificate of conformity, as required by your purchase. These are different documents; avoid asking only for a “certificate” without defining its expected contents.

If your customer specifies a standard, provide its designation, edition and applicable clause, along with the procedure revision. Ask the quotation to confirm the documentation scope and block characteristics explicitly. This guide helps prepare an inquiry; it does not replace an approved procedure or provide calibration instructions.

6. Checklist for an inquiry

  • Application: thickness gauging, conventional UT or Phased Array.
  • Instrument, probe and wedge in use.
  • Block type, part number, drawing and revision.
  • Material, dimensions, units and reflectors.
  • Procedure and required documentation.
  • Quantity, delivery city and country.

UT PROBES LATAM can receive your inquiry and review sourcing feasibility. Part number, documentation, availability and lead time are confirmed in the quotation. If the block is not yet defined, send the technical requirement via WhatsApp to start the review.

Frequently asked questions

Can a step block replace a V1 or V2 block?

Do not assume so. First identify the required adjustment or verification and the block specified by your procedure.

Are all Phased Array blocks the same?

No. Obtain the drawing and review material, geometry and reflectors against the intended work. The term PAUT alone does not define a block.

What should I send without a part number?

Share the application, instrument and technical requirement. If an existing block is available, add photographs of its markings and its drawing or certificate.

Related reading

Technical references

  1. PH Tool — Ultrasonic Test Blocks, step blocks
  2. Sonatest — Calibration Blocks, selection and block families
  3. Eddyfi — Calibration Wizards for PAUT and TFM with Capture Software

Ask about a UT reference block

How to prepare a UT or PAUT calibration block inquiry: application, material, thicknesses, reflectors, drawing and documentation.

WhatsApp · +1 954 880 4033 ↗